Product Information:● overload protection function● Blue backlight ● weight unit: g, ct、oz 、 GN
● automatic shutdown time: 1 minutes
● operating environment temperature: 0°C - 40°C (32°C-104°C)
● power supply: no.7 battery● low voltage display: LO_
● overload display: O_Ld
this paragraph: English copy key in English Manual
correction method
press the mode Key for 3 seconds. The display shows CAL. Let go. Press the mcde key to display 500/2000G. At this time, place 500/2000g weight on the tray, after 3 seconds, 500.00/2000.0G is displayed, and the calibration is completed. (Please use this function if the weighing is not on time due to excessive temperature difference or other reasons)
precautions
1. Gently take the tray protective cover and put the weighing body smoothly without vibration and wind-free environment
2. Do not place any objects larger than the rated weight on the tray, which may damage the sensor. Do not impact the weighing tray when placing objects, and handle them with care. (this is the general pocket scale precautions, this machine is equipped with compression protection settings, which can withstand about 100 Jin pressure without damage).
3. Do not use mobile phones within 50cm around the weighing body when using this product, which will affect the use of this product;
4. When the display screen displays the battery symbol, please replace the battery immediately;
operation method
on/Off
(1) put the electronic scale on a stable desktop, then press the on/OFF key ('ON/OFF key or 'off' key) to turn on, and the display screen displays the boot screen (backlight will be automatically turned on at the same time), "0.0" (or "0.00," 0.000) is displayed after about 1 second, and can be used normally.
(2) in the startup state, press the ON/OFF key ("ON/OFF" key or "OFF" key) once to turn OFF the power.
(3) in order to prolong the service life of the battery, if there is no operation or no change in the number of the display screen under the startup state, the system will automatically turn off the power after 60 seconds.
Clear/peeling function
(1) If "0.0". "0.00" is not displayed after startup, press the "TARE" key (or "T" key) to display zero point, and it can be used normally.
(2) If you want to use other containers for weighing, please put the containers on the scale first, and then press the "TARE" key (or "T" key) after "0.0" (or "0.00," 0.000 ") is displayed, the item is placed in the container. The actual weight of the item is displayed. After the container is removed, a negative number will be displayed, press the" TARE "key (or" T "key) to clear.
Unit conversion function
in the normal weighing state, press the "MODE" key (or "M" key) in sequence to display the weight in different unit modes. For example, g.oz.dwt.ct.gn
accumulation function
under normal weighing conditions, place an item on the scale. After the weight is stable, press the accumulation key ("ADD"), then remove the item and put another item on the scale. After the weight is stable, press and hold the accumulation key ("ADD") if you don't let go, the display will show the total weight of the two items. The weight of multiple items can be accumulated in sequence.
Counting function
3. PCS:
all items must be the same weight
in the normal weighing state, put a certain number of samples to be counted on the scale (the system preset 25.50.75.100 four kinds of samples to choose from), press and hold the "PCS" button, after 2 seconds, the display shows the number of samples, then release the "PCS" key, press the "MODE" key (or "M" key, "UNITS" key), you can switch the number of different samples, after selecting, press the "PCS" button to confirm the number of samples and enter the counting state. If you need to change the number of samples, reset them according to the above steps; press the "MODE" key (or "M" key) in the counting state. "UNITS" key), the system will exit the counting status and return to the normal weighing status to display the weight value.
4. Calibration:
1. The zero range is 2000G, 1000G, 500g , 300g , 200g , 100g , 50g
2. Press [Model] for a long time until 'CAL' appears and then display the calibration weight of the relevant machine.
3. Put ON the required weight and press [ON/OFF]]
4. If 'PASS' is displayed, it can be used normally.
5. Troubleshooting
the main reasons for inaccurate weighing and failure are generally low power, incorrect calibration, overload or failure to operate on a stable surface.
[DISPLAY] indicates removal of errors
[OUT2] indicates re-calibration
[EEEE] indicates that it is overweight and should be taken to some overweight items immediately.
[UN2T] means putting the scale on a more stable platform for weighing
in the normal weighing state, put a certain number of samples to be counted on the scale (the system preset 25.50.75.100 four kinds of samples to choose from), press and hold the "PCS" button, after 2 seconds, the display shows the number of samples, then release the "PCS" key, press the "MODE" key (or "M" key, "UNITS" key), you can switch the number of different samples, after selecting, press the "PCS" button to confirm the number of samples and enter the counting state. If you need to change the number of samples, reset them according to the above steps; press the "MODE" key (or "M" key) in the counting state. "UNITS" key), the system will exit the counting status and return to the normal weighing status to display the weight value.