1. Realize long-distance operation;
2. Realize automatic control;
3. Digital display is intuitive and human error is reduced.
4. High accuracy and resolution;
5. Wide weighing range;
6. Special functions: deduction, pre-deduction, zero, cumulative, warning, etc.
7. Simple maintenance;
8. Small size;
9. Simple installation and correction;
10. Special industry, can connect printer or computer driver;
11. Intelligent electronic scale, quick response, high efficiency;
Health scale
Fault description
1. Maximum weighing: an electronic scale does not take into account the weight, the maximum weighing capacity (full load value), that is, the maximum load that can be weighed;
2. Minimum Weighing: A relative error occurs when an electronic scale is below that value;
3. Safety load: 120% normal weighing range;
4. Rating load: normal weighing range;
5. Allowable error: the maximum allowable deviation in grade verification;
6. Sensitivity: The smallest scale that an electronic scale can display; usually expressed as "d";
7. Minimum scale: take-off value, example: 60Kg * 5g, 5g is the minimum scale, that is, the minimum sensation;
8. Calibration interval: sensation = e, which indicates how much weight each jump will add, such as: 300g * 0.001g, 0.001g is sensation;
9. Calibration interval: If the scale takes off from 10g, how many calibrations are there from 10g to the maximum scale?
For example: 100kg * 10g, (100 * 1000) 10 = 10000, 10000 is the interval of scale;
10. Precision: Ratio of Sensor to Full Weighing. Example: Weighing 6000g minimum scale (sensibility) 0.5g. That is, 05/6000 = 1/12000 1/12000 is the precision of the scale.
11. Electromagnetic interference: The interference caused by radio waves is commonly known as, for example, the radio waves emitted by Big Brother's mobile phone.
12. Analytical Quantity: The smallest scale that can be distinguished by an electronic scale with counting function;
13. Resolution: An electronic scale with counting function and a parameter with internal resolution ability;
14. Internal resolution: that is, internal precision, such as 5 COUNT 1 hop, 5 COUNT is internal resolution.
For example: 100g (weighing) *0.01g (sensing), 5COUNT 1 jump, 0.01g_100g = 1/10000 (precision),
1/10000_5 = 1/50000 (internal resolution), internal resolution is mainly for CPU operation.
Internal resolution is mainly used in counting scales, which is simply the minimum value Counting Scale can count and analyze.
15. Preheating time: the time it takes for a scale to reach all the targets;
16. OFFSET value: Take a value from COUNT as the starting zero value, mainly to keep the scale in normal operation, in order to avoid the occurrence of improper conditions. (count: internal analytic value) when a general scale is set, the software will define the scale of this type - OFF SET value, that is, zero value, which can be used for judgment and basis when adjusting.
17. SPAN value: put the load on the value shown by the scale, that is, SPAN, so that the weight of the scale can be displayed as much as the weight put, so that the scale does not have too much error.
Creep CREEP: After a period of load testing and recording the results, see if there is any change, test results, the size of CREEP. It will depend on the stability of the scale.
19. Hysteresis: Take the weight of equal proportion and put it on the scale and record the displayed weight. Then take the weight of equal proportion off the scale to see if there is any error, which is similar to Q15 linear test, and test whether the recovery is good.
20. Applicable temperature: - 10 ~40 ~C. According to the definition of OIML, if the applicable temperature is not indicated, it is based on it.
21. Humidity: The relative percentage of moisture in the air, too high humidity will affect the linearity and stability of the scale, too low, too dry will produce electrostatic interference.
22. The environmental temperature of the electronic scale is -10 ~40.
23. Table Size of Scale: 25 cm X 30 cm 30 cm X 40 cm X 50 cm 42 cm X 52 cm 45 cm X 60 cm