Welcome! Join free or Sign In

X Email Mobile

Home > Products & Suppliers > Yiwu Production Material Market> 2 F > Plastic particles> Boiler parts factory
yiwu export building roof waterproof material colored steel tile water resistence and leak repairing coiled material renovation self-paste waterproof tape 中文版
  • EXW Price: Min. order:
    ¥13.0
    ≥30/rice
    ¥11.0
    ≥3000/rice
    ¥9.0
    ≥20000/rice
  • 30 rice
  • Item No. 宽1米
  • Stock num 999999 rice
Please select a product
  Number   Unit-price   Total
I want to buy: × 13.0 = 0
The purchase quantity of each ID cannot exceed()rice
Insufficient inventory, please contact the seller
The total number of orders is less than the minimum purchase quantity(30)

A new item has been added to your Shopping Cart. You now have items in your Shopping Cart.

Continue Shopping View Shopping Cart

Boiler parts factory 2yr.

Contacts:

qinChat

Mobile:

86-19858988858

E-mail:

2992183296@qq.com

Click to Contact Yiwugo official customer service for International sourcing.

Yiwugo official customer service X

Whatsapp:

Email: yiwubuy@yiwugo.com

  • Description

Packaging information

CTN Size: 100 × 22 × 22 cm

G.W./CTN:21000 kg

QTY/CTN:39000 rice/carton

Henan Bangda Waterproof Material Co., Ltd. produces color steel sheet roofing steel structure waterproof membrane, self-adhesive butyl waterproof and insulation aluminum adhesive membrane for roof, special waterproof membrane for construction sites, self-adhesive waterproof membrane for cement roof, factory building roof waterproof membrane, building steel structure renovation anti-corrosion waterproof membrane, width 1m x 30m, red, blue, gray, green, black, white, silver, color can be customized.

Color steel sheet self-adhesive waterproof and insulating membrane, dedicated self-adhesive waterproof membrane for full-coverage roofing, metal surface corrosion-resistant waterproof membrane, can last over ten years.
A roof covered with rusty and leaky color steel tiles, cement-painted building roofs, aging and leaky felt sheets, and glass-covered roofs for waterproofing and insulation, with simple construction, no need for fire-baking or glue application, simply paste directly, and can last over ten years.
Application scope, suitable for electroplating, chemical, papermaking, ceramic, breeding, leather, dyeing and printing, high-temperature casting and other industries with severe corrosion, high waterproof and insulation requirements, such as color steel roof of factories, warehouses, and large shopping malls.
Factory direct supply, reasonable price, reliable quality, contact customer service for details, specifications, and colors at 18836999287.Color steel roof construction technology
Color steel sheet self-adhesive waterproof membrane, as a building material, is widely used in industrial plant construction and civilian roof construction due to its light weight, environmental protection, and high cost performance. It is effective in preventing leaks, rust, and rain seepage on color steel sheet roofs.

Waterproofing base condition
1. Ensure that the base surface of the corrugated steel sheet is free from dust and is not loose. If there are loose conditions, they need to be treated before construction can begin.
2. The base surface cannot have water accumulation, and if there is water accumulation, it must be reinforced and treated until it is qualified before the construction of the waterproof layer can begin.
3. When necessary, the gaps in color steel tiles should be reinforced, and then construction can proceed.
4. Additional layers are required for corners of the Yin-Yang angle, the vertical plane, and the plane of the Yin angle, as well as the interior and exterior angles of the elevation.
5. Construction work is to be stopped if dew is found on the color steel sheet roof in the morning.
6. When construction is carried out in severe winter, a primer is needed to be applied to the corrugated steel sheet.

Section Two: Operating Process
1. Clean the base surface: Check the dirt and rust on the base surface, wipe away the dust with a cloth, and if there is any iron rust, it also needs to be removed. Rinse the roof with water to clean it and keep it flat.
2. Make an additional layer: Additional layers are needed at places such as corners with different directions, ventilation openings, and gutters, about 15cm to 30cm in thickness, and they should be extended along the central axis of the corners with different directions.
3. Construction: First use the baseline, and the rolled material laid out will achieve a neat and beautiful effect; align and position the rolled material with the construction area, and you can roll up the material from both sides; cut the isolation paper from the middle, and as you peel off the isolation paper, squeeze the rolled material to maintain its flatness.
4. Requirements: When laying the membrane, start from the direction of the water flow, and start from the top down on the vertical wall. To eliminate air, roll the membrane to squeeze the air inside, thereby achieving a firm adhesion effect of the membrane; when the temperature is low, both the membrane and the base layer need to be coated with a base treatment agent; the length of the membrane overlap on the long side is 3cm~8cm, and the short side is 10 cm; the exposed short side overlap of the membrane and the membrane ends need to be sealed with sealant.
Color steel roof construction technology
Section Three: Tiling Methods
The method of covering: apply waterproof membrane specially designed for color steel roofing on the entire surface of the color steel roofing, which can ensure the roof is fully waterproof and corrosion-resistant.
Section 4: Construction Precautions
1. The roof should not have any dust. If a coating agent is needed, it should not be too thick.
2. The thickness should be selected between 1.5mm and 2mm.
3. Construct only when conditions are suitable. Do not begin work on foggy days or immediately after heavy rain, as moisture can cause air bubbles.
4. The overlap of the long and short edges of the membrane should be at least 10cm.
The overlap between the roofing sheets and between the roofing sheets and the reinforcing layer must be firmly fixed.
6. For newly constructed waterproof layers, they should not be casually removed, as the longer the bonding time, the more firmly the material adheres. If the layer is removed more than twice, it is easy to experience poor bonding. It is essential to apply a primer to ensure complete bonding.
7. When the temperature of the roof is too high, it is not recommended to store a large amount of materials on the roof. It is better to use one roll and place it, to avoid making it difficult to peel off the isolation film of the roofing material.
Please contact customer service for specific details at 18836999287.

Update time:20251129105529


Chat withX

Supplier> Sourcing Agent>
©2025 Yiwugo.com All rights reserved.
Finding high quality products in Yiwu China, Yiwu China Commodity Market (Yiwu wholesale market), the World's Largest Commodities Trading Center Online.
TEL: +86-579-81530000 FAX: 86-579-85188202 网站备案号:浙ICP备15028362号-7

TOP