Welcome! Join free or Sign In

X Email Mobile

Bao Baoer temperature gun temperature measurement infrared thermometer baby ear thermometer

Bao Baoer temperature gun temperature measurement infrared thermometer baby ear thermometer

Bao Baoer temperature gun temperature measurement infrared thermometer baby ear thermometer Bao Baoer temperature gun temperature measurement infrared thermometer baby ear thermometer Bao Baoer temperature gun temperature measurement infrared thermometer baby ear thermometer Bao Baoer temperature gun temperature measurement infrared thermometer baby ear thermometer
QR code0
[Scan the QR code, view in your mobilephone.]
  • Updated: 2021-08-21 17:12
EXW Price:
100pcs ~299pcs   CN ¥ 45 /pc
300pcs ~999pcs   CN ¥ 44 /pc
Above 1000pcs   CN ¥ 43 /pc
Send Inquiry
Contact
Main
Products:
home supplies
Contacts: Yang JuxianChat
Mobile: 86-13516927842
E-mail:
WeChat: yjx186718
Address: 18671 , 5 Street, 3 F, 45 Gate, International Trade Mart (District 2).



Baby fever, body temperature is young parents the most headache thing, because the general ear thermometer measuring time long, the baby often "cooperation". Now has our products, just to the baby's ear a release, less than a second, the temperature of the number of immediately accurate display, regardless of lying or sitting can be used, the child no pain! It is suitable for everyone, young and old women and children are more suitable!

Technical characteristics: (single or double scale display)
1) display range: Uncertainty of 34.0~44.0oC/93.2~111.2oF
2): 0.2oC/ + 0.4oF
3) resolution: 0.1
4) memory function: The last 10 measurements
5) measurement time: 6) 1
beepprompt function: The end of the measurement by beepprompt
7) automatically shut down: No operation after 1 minutes automatic shutdown
8) battery: 3V button battery (LR/CR 2032) 9)
battery life: About 4000 measurements
Size 10): 110 x 35 35mm
x 11) net weight: 36g (including battery)
12) safety and health

We have to check the product before delivery, to ensure that the product quality 100% sent out. Return all need to receive the goods and objection, please within 3 days from the date of receipt timely and contact us and deal with the matter, should also pay attention to product packaging intact and does not affect our second sale, according to us with the return address in the form of express sent, we after receiving the return confirmed no mistake should refund, return in time. Back to the shipping costs will be required to bear their own.

ear thermometer Chinese use ear thermometer usage: 1 simple steps to measure
: Press "on/recall" key to open the ear temperature gun (with Feng Mingsheng), ready to measure, the screen shows "0". Press the "scan" button to let go
2. Temperature scanning, ear temperature gun will continue to temperature scanning, LCD screen will show the temperature scanning the highest value, and heard the buzzing prompt. If you need to re test, please release the "scan" button, waiting for the top right corner of the screen small ear icon? "After the appearance, re measurement.
3 measurement of the value of storage when the release of the "scan" button. The scan end temperature and the highest temperature measurement values will be displayed on the LCD screen, and memory storage. 4
memory search continues to press "on/recall" key, the last 10 groups (No.9~No.0) measurements will be displayed on the LCD screen one by one. 5
shutdown will automatically shut down if the ear temperature gun without any key operation in 1 minutes when.

Warm tip: 1
infrared ear thermometer is used for measuring the temperature of the human ear canal, compared with ordinary electronic thermometer, measuring principle and measuring parts are different, they can not get the same measurements, the following is an important concept of judgment:
temperature a) temperature is the normal value of a range that is not a certain constant value, everyone is different;
b) normal body temperature, measured in different parts of the body are not the same, not be used to compare the ear temperature the most accurate, most sensitive;
C) temperature change with age, sex, time, sports, mood changes;
D) can measure the temperature in you and your family health, in order to have a fever when compared to future.

2. The infrared ear thermometer is a high-tech, high sensitivity of the measuring instrument, in the use of the process, on the operating environment, measurement method (whether the alignment of the eardrum) have higher requirements, so easy to cause artificial inaccuracy, rather than of the instrument itself, with specific attention to matters: {an a) infrared ear thermometer must be in the operational environment stable for 30 minutes before measurement; measuring head
b) ear temperature gun should be as far as possible deep into the ear canal to paste into the eardrum

36 DEG C ~37.3 DEG C (96.4 ~ F~100.4 DEG F) temperature of the normal range of human, of course, normal temperature will vary from person to person, please to qualified physicians to consult relevant details. Below
as the reference values of the normal body temperature:
ear temperature: 35.7 DEG C ~ 37.5 degrees
Anal temperature: 35.7 DEG C ~ 37.5 C export temperature: 35.5 degrees ~ 37.5 degrees
axillary temperature: 34.7 DEG C to 37.3 degrees but due to the body temperature of a human body with different age and the environment will vary, so above value is not the absolute value, just a numerical reference.
0 ~ 2 years old: 36.4 degrees C ~ 38.0 degrees C
3 ~ 10 years old: 36.1 degrees C ~ 37.8 DEG C
11 ~ of 65 years old: 35.9 degrees C ~ 37.6 degrees C
over the age of 65: 35.8 degrees C ~ 37.5 degrees Celsius

Why use the left and right ear thermometer to measure the temperature will be different? The left and right
because everyone's ear is not the same, so the measured temperature is It differs from man to man. The general difference between 0.5 DEG C, also has a difference of up to 1 DEG C, but there are few people left, right ear temperature is the same.

Why ear thermometer for continuous measurement of 3, 4 times, each time the temperature will not be the same?
ear temperature Jigang from the basin in out, haven't adapted to environmental temperature, so the continuous measurements will appear different data, the same will also occur in room temperature difference are too much room. For example: with the temperature of the furnace room to much higher than the other, rapid changes in environmental temperature is also caused by one of the reasons for the inaccuracy of ear temperature gun numerical. So in this case, it is recommended that the user first ear temperature gun placed in the room, about 20 minutes later, so that it can adapt to the environment temperature, so you can get a more correct value.

Is the time of the ear thermometer really just a second? This is really
oh! Our body temperature will emit infrared rays, so the sensitivity of infrared ear thermometer sensor can easily sense our body temperature. Breakthrough the traditional mercury thermometer to measure, to know, how long to limit where, now you only need to be ear thermometer gently into the inside of the ear measure, key seconds after you hear the beep, you can measure temperature changes. Moreover, mother to let the restless baby quiet down for a few minutes and is not an easy thing, squirming baby if a accidentally put thermometer bitten or break is too dangerous, infrared ear thermometer spectrophotometer overcomes the traditional mercury thermometer safety concerns, let mommy, daddy, then there is no need to worry about.

Does ear thermometer need regular maintenance? Meter
ear temperature is the development of health care products of course or the timing of DIY maintenance, you can use a soft cloth to wipe or plastic chassis special cleaning agent, do not use benzene solvents chemicals. The probe lens is the most sensitive part of the ear thermometer. Please use a mild detergent. As long as the usual attention to cleaning, do not need much maintenance.

Ear thermometer is waterproof?
should pay attention to oh! The thermometer is not waterproof, so shall the thermometer immersion or placed in other liquids, in order to avoid damage! And should keep dry and avoid 10 DEG to 40 DEG (50 DEG F to 104 DEG F) temperature range of direct exposure to sunlight.

After the ear thermometer measuring earmuffs can be reused?
if hospitals and clinics and other public places, taking into account the health, here we have B can replace earmuffs, avoiding cross infection. Families are not required to replace the earcap of, measured before should note film earcap is broken, the way to remind you of ear temperature measurement should pay attention to whether earwax in the ear canal, avoid sticky wax on the earmuffs and the measurement is not accurate.

Ear thermometer about how long it can be used to change the battery?
ear thermometer use a lithium-ion battery (CR2032) is generally used about 4000 times, battery life will vary based on your usage frequency, when the ear thermometer liquid crystal display at the top left of the screen the battery icon flashing for the blank, ear thermometer battery, please replace with new batteries. Battery general stationery stores and supermarkets are sold, but also not expensive, so please do not worry about the battery problem.


Click To Contact Yiwugo's Partner To Get Trade Service
©2024 Yiwugo.com All rights reserved.
Finding high quality products in Yiwu China, Yiwu China Commodity Market (Yiwu wholesale market), the World's Largest Commodities Trading Center Online.
TEL: +86-579-81530000 FAX: 86-579-85188202 网站备案号:浙ICP备15028362号-7

TOP

Items have been added to the Inquiry Basket

There are items in the inquiry basket

Continue shopping Send Inquiry