Search history
Clear allSearch by image
XDrag and drop an image here or upload an image
Max 5MB per image
UploadSign In | Join
X Email Mobile
Juqiang Electromechanical Co., Ltd. 14yr.
Contacts Wang Santong Chat
Mobile 86-008657981556151
E-mail 382297022@qq.com
WeChat 18257005898
| Rated Voltage: | 220 (V) | Maximum work pressure: | 0.8 (Pa) |
| Rated Current: | 10 (A) | Custom Processing: | Yes |
| Type: | Mechanical Pressure Switch | Model Number: | Single-phase four-ventilation pressure switch |
| Brand: | Various | Purpose: | For air pumps and low-power air compressors |
| Mechanical Lifespan: | 10,000 (times) |
When the air compressor is operating, the pressure switch’s two contacts are in a closed state. Compressed air enters the switch terminals and the vent valve from the air reservoir. When the pressure in the air reservoir reaches the preset upper limit of the switch, the pressure passes through the air cushion top control bolt, causing the pressure control rod to move upward. Under the action of the spring, the moving and stationary contacts at the electrical contact point are quickly disengaged. The power is cut off, the motor stops working, and the vent valve rod is also pressed down, allowing the compressed air in the pipeline to be discharged through the vent valve, thereby reducing the starting load on the motor.
Conversely, when the pressure in the gas storage tank drops below the lower limit, the aforementioned components move in reverse, connecting the circuit and causing the air compressor to start operating again.
<t)_Note: The control bolt on the top of the switch operates when pulled out and stops working when pressed down_.



Update time:
TOP