Welcome! Join free or Sign In

X Email Mobile

Home > Products & Suppliers > International Trade Mart (District 4)> 5 F > Daily Necessities> yiwu ange medical instrument co.,ltd
vacuum blood collection tube heparin lithium tube negative pressure blood collection tube coagulation promoting tube plasma tube serum tube 中文版

    Price Negotiable

Send Inquiry

A new item has been added to your Shopping Cart. You now have items in your Shopping Cart.

Continue Shopping View Shopping Cart

yiwu ange medical instrument co.,ltd 11yr.

Main Products:

Medical equipment,non-woven fabric products,measuring pregnant card,bandage,bandages,plasters and masks,cooling,medical gloves,first aid kits,disposable underwear

Contacts:

AnnaChat

Mobile:

86-18205891975

WhatsApp:

18205891957

E-mail:

2427910563@qq.com

WeChat:

Medical18205891957

Address:

50312 , 1 Street, 5 F, 75 Gate, International Trade Mart (District 4).

Address:

Yiwu,Jinhua City,Zhejiang Province

  • Description


  We have various specifications. If you have any needs, you can directly go to our store to see the samples. From the 4th floor to the 5th floor of the North Gate, to the 5th floor of the 75th door, to the 5th floor of the 1st street, 50312, 50310, and 50308. Warmly welcome your arrival!!!

Our vacuum blood collection tubes are top-quality and beautifully packaged products from Jiangsu!! 

Disposable vacuum blood collection tubes, different colored lids represent different types of blood collection tubes, and the products use glass test tubes and PET plastic materials.


 

No additives:
Used for the collection and storage of biological specimens in medical laboratory tests such as biochemistry, immunology, serology, various bacterial detection, and blood bank testing. The tube wall is specially treated to prevent the occurrence of wall adhesion and hemolysis; it is also used for the collection of blood specimens for hematology tests.

Blood collection tube, also known as a testing tube.

   Color code: Red

  Specification: 13×100mm

  Regular Blood Collection Volume: 5ml

  Blood coagulation time: ≤ 2.5 hours

  Maximum Centrifugal Speed: 3500-4000 RPM

  Operating environment temperature: ±10%.

  Operating Notes: If the blood collection does not reach the prescribed volume, please clear the vacuum in the tube.

 

Separation gel + coagulant
Used for serum biochemistry tests, immunological detection, drug detection, etc. The tube wall is uniformly coated with a coagulant, which can greatly shorten the blood coagulation time. The use of imported separation gel makes it less likely to absorb proteins in serum.

The stability is strong, and the separation gel after centrifugation forms a barrier to completely separate serum from blood cells, effectively preventing material exchange between them, obtaining high-quality serum, making blood tests

The result is more realistic, which improves the collection rate of serum. It can also extend the storage period. It can be directly put on the machine without blocking the probe channel.

   Color code: Yellow

  Specification: 13×100mm

  Common blood collection volume: 5ml

  Blood coagulation time: 10-20 minutes

  Maximum Centrifugal Speed: 5000 RPM

  Operating temperature: 0°C - 37°C

  Maximum Vacuum Error: ≤10%

  Operating Notes: a After drawing blood, immediately invert gently 180° 5-6 times.

                In order to better form a colloid barrier, after the blood completely coagulates, centrifuge for 8-10 minutes.

 

Thromboplastin:

The collection of blood specimens for biochemical and immunological tests in medical diagnostics. The inner walls of the blood collection tubes are uniformly coated with a detergent to prevent clinging, and at the same time, the tubes contain a coagulant to facilitate blood clotting. These tubes offer a wide operating temperature range.

The blood coagulates quickly and does not exhibit secondary fibrin precipitation phenomena, among other advantages.

    Color code: Orange

   Specification: 13×100mm

   Regular blood collection volume: 5ml

   Blood coagulation time: 10-20 minutes

   Maximum Centrifugal Speed: 5000 RPM

   Operating temperature: 0°C - 37°C

   Maximum Vacuum Error: ±10%

   Coagulation time: when platelet function is unimpaired, the coagulation time is ≤5 minutes

   Operating Notes: a. After drawing blood, immediately invert gently 180° 5-6 times, and make sure the blood completely coagulates.

                   Centrifuge for another 5-10 minutes.

                 If the blood collection does not reach the prescribed volume, please clear the residual vacuum in the tube.



3.2% Sodium Citrate 1:9 (Citric Acid Sodium)
Used for coagulation mechanism and other tests, the vacuum blood collection tube with a ratio of anticoagulant to blood sample volume of 1:9, with a constant anticoagulant ratio of 0.109 mol/L, has high precision in ratio. Since citric acid is less toxic, it is also used.

For blood preservation.

    Color code: Blue

   Specification: 13×75mm

   Common blood collection volume: 1.8ml

   Additive Type: 3.2% Sodium Citrate

   Operating temperature: 0°C - 37°C

   Operating Notes: a. After drawing blood, immediately invert gently 180° 5-6 times.

                 Please note to collect enough blood when drawing blood to ensure the accuracy of the test results.

                 When using a soft-connected, bidirectional blood collection needle for blood collection, it should not be the first tube to be collected.

 

EDTAk2 (Anticoagulant): (Blood routine tube, Anticoagulation tube)
Used for clinical hematology testing and suitable for all types of blood cell analysis. The inner wall of the blood collection tube is coated with a medication to prevent clumping, and at the same time, it contains an anticoagulant. EDTA anticoagulant prevents the clumping of blood cells and the

The effect on shape is minimal, and it can inhibit platelet aggregation.

    Color code: Purple

   Specifications: 13×75mm 13×100mm

   Regular Blood Collection Volume: 2ml 5ml

   Additive types: EDTAK2, EDTAK3, EDTANa2

   Operating temperature: 0°C - 37°C

   Maximum vacuum error ±10%

   Operating Notes: a. Immediately after drawing blood, gently invert and mix 5-6 times.

                 Please note to collect enough blood when drawing blood to ensure the accuracy of the test results.

 


Sodium Heparin/Lithium
Blood specimen collection for clinical biochemistry, emergency biochemistry, and hemorheology measurements. Minimal interference with blood components, does not affect red blood cell volume, and does not cause hemolysis. Features a fast plasma separation speed, and does not interfere with blood coagulation.

The advantages of the clear specimen indicators include strong compatibility.

   Color code: Green

  Specification: 13×100mm

  Regular blood collection volume: 5ml

  Additives: Sodium Heparin, Lithium Heparin

  Maximum Centrifugal Speed: 5000 RPM

  Maximum Vacuum Error: ±10%

  Operating Notes: a. After drawing blood, immediately mix 180° for 5-6 times.

                Collect enough blood for testing. Avoid increasing heparin concentration, which may affect the determination of calcium.

                Heparin anticoagulation should be used within 6 hours, otherwise the blood will coagulate again.

 

Sodium fluoride + potassium oxalate
Blood samples for the detection of glucose, glucose tolerance, erythrocyte electrophoresis, methemoglobin, and sugar-induced hemolysis are collected and anticoagulated. The addition of inhibitors and special treatment of the tube walls make it possible to detect these items.

The original state of blood is maintained for 72 hours, and the metabolism of blood cells is essentially stagnant, etc.
Color code: gray

  Specification: 13×75mm

  Common blood collection volume: 2ml

  Additive types: Sodium Fluoride + Potassium Oxalate, Sodium Fluoride + Sodium Heparin

  Maximum Centrifugal Speed: 5000 RPM

  Maximum Vacuum Error: ≤5%

  Operating Notes: Due to the fact that sodium fluoride has a good effect in preventing and treating blood sugar degradation, it is recommended that after blood collection, the sample should be gently inverted and mixed slowly for 5-6 times at 180°.



Citric Acid and Sodium Citrate 1:4
Point specifically for Wei's erythrocyte sedimentation rate (ESR) test, including blood collection and anticoagulation. The ratio of anticoagulant to blood volume is 1:4.

  Color code: Black

  规格:13*75mm

  Common blood collection volume: 1.6ml

  Additive Type: 3.8% Sodium Citrate

  Maximum Vacuum Error: ≦5%

  Operating Notes: a. After drawing blood, immediately invert gently 180° 5-6 times.

                  Please note that when drawing blood, ensure that the blood volume is sufficient to ensure the accuracy of the test results.

Wei's erythrocyte sedimentation rate:
The tube is specially used for the collection and anticoagulation of blood samples for the Weigert's erythrocyte sedimentation rate (ESR) measurement.

  Color code: black

  Anticoagulant types: 3.8% Sodium Citrate

  Anticoagulant form: aqueous solution

  Common Specifications: 8×120mm

  Rated Blood Collection Volume: 1.28ml

  Anticoagulant to blood sample volume ratio: 1:4

  Vacuum Error: ≤5% 

 

We can issue ordinary tax invoices or value-added tax invoices with additional charges. If you have any needs, please contact us directly. Thank you, and have a pleasant cooperation!

Reminder: If Yiwu Buy is offline or no one responds, please contact the other methods below, thank you! 

 


If needed, please contact QQ: 3547068691.

Phone: 18758910919, Mr. Ma


 



Update time:20230725160429


©2024 Yiwugo.com All rights reserved.
Finding high quality products in Yiwu China, Yiwu China Commodity Market (Yiwu wholesale market), the World's Largest Commodities Trading Center Online.
TEL: +86-579-81530000 FAX: 86-579-85188202 网站备案号:浙ICP备15028362号-7

TOP