Model KDZF700/500 features a built-in camera system and a shadowless surgical lamp
Technical specifications: --- Centralized digital image surgical shadowless lamp (with monitor)
1. Resolution: ---------------------- ≥540TVL
2. Signal-to-noise ratio: ---------------------- ≥540TVL
3. Camera distance: ------------------- Main camera (installed on the main light) 0.8~2m
-------------------- Sub-camera (panoramic camera) 1~10m
4. Input Power (w): ----------------- 900w
5. Cloud platform rotation range: ----------------- Horizontal ≥ 180°
6. Illumination: -------------------------- Main light: 80,000~180,000
----------------------- Aux light 60,000~150,000
7. Power supply voltage: -------------------- ~220V / 50Hz
8. Camera Aperture: ---------------------- F1.6 ~ F3.7
9. Focal length: --------------------------- F3.9 ~ F8 5.8 mm
10. Multiple: -------------------------- 22 times
11. Video Output: ---------------------- 1.0 VP ~ P75Ω
1 2 Camera Power Supply: ---------------------- 1 2VDC ± 10%
1.3. Main light and auxiliary light automatic switching: ------------- 0.2 seconds (automatic)
4. Six-dimensional joints: ------------------- 360°
1.5 Minimum installation height: ----------------- 3,000 mm
16 Camera Workbench: ---------------------- √ √
17 Camera System Brand: ------------------- Panasonic, Japan
18. Built-in recording system, video recording system
19. The main camera is hidden within the main light, and the secondary camera (i.e., panoramic camera) is mounted on a tripod.
20. A built-in multimedia burning system for real-time recording of the surgical process
Instructions:
1.KDZF700/500 The digital image surgical shadowless lamp system consists of primary and secondary cameras, a multimedia computer digital monitoring system, a display, and a surgical shadowless lamp.
2. The main camera is designed on a balance system with 360° adjustment, resulting in better imaging performance. Additionally, this design ensures clearer image rendering.
3. The secondary camera mounted on the gimbal captures the entire scene, expanding the monitoring range.
4. The system integrates various advanced technologies such as high-sensitivity integrated digital cameras and multimedia computer digital monitoring systems.
5. The zoom lens offers a 22x zoom, which is convenient for observing the full-body surgical scene and for making local magnification images.
6. The multimedia computer digital monitoring system provides:
a. Monitoring function: 4-screen split display for real-time viewing
b. Recording function: All footage is recorded in real time
c. Follow-up function: You can use the replay button to play back images
d. Network Features: Provides local area network and remote network transmission interfaces
7. The time generator is used to display the surgery date, time, and patient name for video identification.
8. Equipped with accessories for editing, modifying, and storing video materials.
Our advantages:
1. Utilizing advanced CAD/CAM integrated reflection technology ensures that each lamp body achieves over 5280 multi-mirror reflections.
2. The light panel is molded using German PC (bulletproof glass) injection molding.
3. In addition to the main camera on the lamp head, there is also a panoramic secondary camera.
4. All products utilize technology introduced from Germany, ensuring quality and offering competitive pricing.
5. National mobile after-sales service, ensuring technical personnel arrive at the site within 48 hours
Description of the ten advantages of the parameters:
1. German imported balanced light arm, made of a smoldering-grade material, compliant with ICE standard requirements
2. Six sets of universal joints for the German original imported spring cantilever suspension system, with a full-angle design of 360° joint linkage, ensuring precise positioning and completely eliminating drift;
3. Imported Osram bulbs with a service life of ≥1000 hours, featuring an automatic switch-off mechanism in 0.2 seconds, which does not affect the illumination intensity or surgical area.
4. Advanced CAD/CAM optical reflection technology from Europe, featuring over 5280 lenses, achieving near- daylight conditions and shadow-free surgery;
5. German imported aluminum materials, treated using patented oxidation technology, have a lifespan five times longer than coated reflection systems for mirror applications;
6. Experts recommend thermal energy technology, which filters out 99.5% of infrared rays, causes a temperature increase of 11° in the patient’s injured area (≤ 12° according to international standards), and prevents the risk of water evaporation within the surgical area;
The light bulb automatically switches at 7.0.2 seconds, without affecting the illumination intensity or surgical area.
8. The power switch, brightness adjustment, and auxiliary light detection are integrated, with a ten-step brightness adjustment memory function, making it easier for physicians to operate;
9. The streamlined light head design facilitates the use of laminar flow in operating rooms and meets the sterility requirements for clean surgeries;
10. The expert-designed calibration system provides a color temperature of approximately 4500K, similar to natural sunlight, ensuring that surgical physicians can clearly and accurately identify colors such as blood vessels and nerve bundles within the surgical area.