Features:
CMS9000 multi-parameter monitor
Features
1. Color TFT screen, waveform up to 8 channels
2. Portable with built-in rechargeable battery
Three. Up to 10 Monitor Parameters
4. Arrhythmia analysis, velocity marker detection and S-T Segment Analysis
5. 72-hour trend chart and table storage and Review, 40-second color wave rms review.
6. Built-in recorder (optional)
7. All-round monitor for adults, children and newborns.
8. Electrosurgical device and Defibrillation protection
9. Standard parameters: ECG, NIBP, SpO2, respiration, temperature, pulse rate
10. Optional parameters: ETCO2, CO, IBP, and thermal printer
Electrocardiogram
1. 5 Lead or 3 Lead optional
2. Input: 5 leads: RA;LA;RL;LL;V or R;L;N;F;C
Three. Wire selection: I;II;III;AVR;AVL;AVF;VX;CAL
4. Gain selection: 12.5mm/second, 25mm/second, 50mm/second
5. Accuracy: ± 1bpm or ± 1%, whichever is greater.
6. Protection: can withstand 4000Vac/50Hz voltage under the condition of Electrosurgical and defibrillation isolation.
7. Calibration signal: 1mV ± 5%
8. Operation modes: diagnosis, monitoring, and surgery
9. Alarm range: Adult: 15-300bpm
10. Pediatrics/newborn: 15-350bpm
11. Alarm range:-2.0mv to 2.0mv
12. S-T detection: Yes, arrhythmia analysis: Yes
13. Alarm: Yes, sound and light alarm, alarm events can be recalculated
NIPP
1. Method: oscillometry
2. Operation mode: manual/automatic/static
Three. Unit of measurement: mmhg/kpa optional
4. Measurement type: contraction, relaxation, and average
5. Measurement range: Adult: 10-270mmHg
6. Overpressure protection: Yes
7. Resolution: 1mmHg
8. Accuracy: average error and standard deviation according to ANSI/AAMI SP-10
9. Alert: contraction, relaxation, and average
SpO2
1. Measurement range: 0-100%
2. Accuracy: ± 2 degrees (70 ~ 100%);
Three. 0 to 69% not specified
4. Alarm range: 0-100%
Breathing
1. Method: RA-LL impedance
2. Pediatrics/newborn: 6-150rpm
Three. Alarm range: Adult: 6-120rpm
4. Pediatrics/newborn: 6-150rpm
5. Apnoea alert: Yes
Temperature
1. Resolution: 0.1°C
2. Channel: Dual Channel
Three. Alarm range: 0-50°C
Options:
ETCO2
1. Measurement Method: lateral flow or mainstream
2. Measurement range: ETCO2:0-99mmHg
Three. Accuracy: carbon dioxide concentration
4. Apnoea alert: Yes
Carbon monoxide
1. Method: thermal dilution
2. Measurement range: CO:0.1-20 liters/minute.
IBP
1. Channel: 2 channels
2. Pressure Sensor: Sensitivity: 5(mv/v/mmhg)
Three. Sensor location: ART, PA, CVP, RAP, LAP, ICP
4. Alarm range: 10 to 300mmHg
Standard parameters and configurations
ECG, NIBP, SpO2, respiration, temperature, pulse
Optional parameters and configurations
ETCO2, IBP, thermal printer