Technical parameters
Temperature measurement range: -50 ℃∽ +300℃ (-58℉∽+572℉)
Resolution: 0.1°C
Accuracy (-20°C to 80°C) ±1°C
Voltage: DC 1.5V
Features • Temperature measurement and memory function • Temperature measurement and low voltage display function •
Energy-saving feature: The device will automatically turn off if there is no operation within 15 minutes.
Sensor fault display • Fahrenheit and Celsius display function conversion
Operating Instructions • [ON/OFF]: Press this button to turn on or off the device. After turning on for 1.5 seconds, the last measured temperature will be displayed, and then the device will enter the measurement mode. If no operation is performed, the device will automatically turn off after 15 minutes.
• [ ℃ /℉]:In the temperature measurement mode, press this button to achieve the conversion between Celsius and Fahrenheit. • Low voltage warning for temperature measurement and display: If the voltage is lower than 1.3V, the LCD will display "Low voltage". • When the sensor is open circuit or below the measurement range, it will display E00. When the sensor is short-circuited or the actual temperature is higher than the measurement range, it will display E11.