CMS8000VET veterinary monitor has rich functions and can be applied to the monitoring of cats, dogs and other animals. Users can also select different measurement parameter configurations according to different needs. Portable monitor uses 50Hz,220V mains power supply, 12.1 inch color TFT display displays real-time data and waveform, and can display the waveform and all monitoring parameters at the same time. It is connected with the monitoring system of our company through wired or wireless network to form a network monitoring system.
This monitor can Monitor ECG, RESP, NIBP, SpO2, dual-channel TEMP and other main parameters. It integrates the function, display and recording output of the parameter measurement module to form a compact and lightweight monitor. Its replaceable built-in battery provides convenience for moving.
Product function description
Standard parameters: ECG, respiratory (RESP), blood oxygen (SpO2), pulse rate (PR), Non-Invasive Blood Pressure (NIBP), dual-channel body temperature (TEMP)
1)ECG heart rate (HR)
ECG waveform
Arrhythmia and ST Segment Analysis
2)RESP respiratory rate (RR)
Respiratory waveform
3)SpO2 oxygen saturation (SpO2)
Pleth waveform
Pulse rate (PR)
Bar chart
4)NIBP systolic pressure (SYS), diastolic pressure (DIA), MEAN pressure (MEAN)
5)TEMP T1,T2,TD
The monitor has rich functions and can provide functions such as acousto-optic alarm, trend storage and output, NIBP measurement, alarm event identification and drug calculation.
Product Features
1)12.1-inch color TFT LCD display, multi-language operation interface (simplified Chinese, Traditional Chinese, English, French, German, Turkish, Spanish, Portuguese, Italian, Dutch, Romanian, Russian, kazakh, Polish, Czech)
2) fan-free design, quiet, energy-saving, clean, does not affect rest, while reducing the possibility of cross infection
3) it has standard interface, respiratory oxygenation diagram, trend coexistence interface, large character interface and bed observation, which is convenient for users to observe
4) all operations can be completed through button and knob
5) display 8 waveform at large time
6)7-lead ECG display on the same screen, ECG waveform cascade display
7) digital blood oxygen technology, anti-motion interference, anti-ambient light interference, can be measured during weak perfusion
8) Non-Invasive Blood Pressure Measurement Method: manual, continuous, and interval measurement optional, 4800 groups of blood pressure data storage
9) 71 alarm events review of all parameters and 60 arrhythmia alarm events Review
10) function of drug concentration calculation and titration table
11) one-click printing of trend table data
12) support 3G/WiFi/Wired networking to realize monitoring system
13) built-in rechargeable lithium battery, AC/DC dual-use, can realize uninterrupted monitoring
14) anti-high frequency electric knife, protection against defibrillation effect (special lead wire is required)
product Performance
▲ ECG
Lead Mode 3/5 lead optional
Optional leads I,II,III,aVR,aVL,aVF,V
Waveform 5 Leads 2 channels
3 Lead 1
Gain 2.5mm/mV,5.0mm/mV,10mm/mV,20mm/mV,40mm/mV
Scanning Speed 12.5 mm/s,25 mm/s,50 mm/s
Heart rate
Measurement and alarm range: 15 to 350bpm
If the display error is ± 1% or ± 1bpm
Alarm error ± 2bpm
Resolution 1bpm
ST segment detection
Measurement and alarm range-2.0mV ~ + 2.0mV
Measurement accuracy-0.8mV ~ + 0.8mV ± 0.04mV or ± 10%
Other scope not defined
Arrhythmia
Category arrest, ventricular fibrillation/ventricular tachycardia, single ventricular premature, two ventricular premature, multiple ventricular premature, ventricular premature two-way rhythm, ventricular premature three-way rhythm, R ON T, missed stroke, tachycardia, bradycardia, pacemaker not captured, pacemaker not pacing
Pacing analysis includes
▲Breathing
Mode R-F(RA-LL) impedance method
Respiratory rate
Measurement and alarm range: 0 to 150rpm
Resolution: 1rpm
Measurement error ± 2rpm
Alarm error ± 3rpm
Suffocation alarm 10~40 seconds
Scanning Speed 6.25 mm/s,12.5 mm/s,25 mm/s
▲ Non-Invasive Blood Pressure
Measurement mode oscillation method
Working mode manual/automatic/continuous
Measurement interval of automatic measurement mode
1/ 2/ 3/ 4/ 5/ 10/ 15/ 30/ 60/ 90/ 120/ 240/480/960 minutes
The measurement time of continuous measurement mode is 5 minutes.
Measurement and alarm range: 10 to 270mmHg
Resolution: 1mmHg
Cuff pressure accuracy ± 3mmHg
Measurement accuracy
Large average error ± 5 mmHg
Large standard deviation 8mmHg
Overvoltage protection
Other 297±3 mmHg
Dog 240±3 mmHg
Cat 147±3 mmHg
▲ blood oxygen
Measurement and alarm range 0 ~
Resolution: 1%
Accuracy 70 ~,± 2%;0~69% is not specified
▲ pulse rate
Measurement and alarm range: 30 to 250bpm
The measurement error ± 2bpm or ± 2% is taken as a large value.
▲ body temperature
Number of channels dual channel
Measurement and alarm range: 0 to 50 ℃
Resolution 0.1 ℃
Accuracy ± 0.1 ℃
▲ power supply 220V,50Hz
▲ type I CF anti-defibrillation application part
accessories
1) Digital DB7 veterinary tongue clip blood oxygen probe (1m)
2) extension cable of common digital blood oxygen probe (2m)
3) newborn capsule single tube repeatability cuff (6-11cm)
4) Non-Invasive Blood Pressure extension tube
5) five Guide electrocardiogram leads (American Standard)
6) ECG veterinary clamp (* 5)
7) body cavity type temperature probe
8) power cord
9) instruction manual
physical characteristics
Size: 314mm(L)× 145mm(W)× 264mm(H)
Weight:<3.0kg (without accessories)