Welcome! Join free or Sign In

X Email Mobile

Siemens Siemens Simatic S7-1500 中文版

Siemens Siemens Simatic S7-1500

QR code0
[Scan the QR code, view in your mobilephone.]
  • Updated: 2022-12-16 17:26
EXW Price:
Above 1pcs   CN ¥ 5,950 /pcs
Send Inquiry
Contact
Main
Products:
Siemens industrial automation products Siemens PLC inverter low-voltage contactor miniature circuit breaker
Contacts: Huang TingChat
Mobile: 86-13811814778
E-mail: ht@gongboshi.com
WeChat: 13522565663
Address: Room 401, Floor 4, Building 3, No. 4, Dongtucheng Road, Chaoyang District, Beijing,Chaoyang District,BeiJing City,Beijing Province

Siemens 6ES75317QD000AB0 SIMATIC S7-1500

AI 8XU/ I /RTD/TC ST

 
 
  • product information details
  •  
  • technical data
  •  
  • CAx data

technical data

SIMATIC S7-1500, analog input module AI 8xU/I/RTD/TC ST, 16-bit resolution, accuracy 0.3%, 8 channels, divided into groups, each group 8, 4 channels common mode voltage 10V when measured with temperature sensor RTD; Diagnosis; Process alarm includes feed element, shield bracket and shield terminal: front connector (screw terminal or embedded) order separately
general information
product Type mark AI 8xU/ I /RTD/TC ST
hardware function status FS04
firmware version V2.0.0
● updatable firmware yes
product Features
● I & M data yes; I & M0 to I & M3
● variable measurement range no
● variable measurement value no
● measurement range adjustment no
with package
● STEP 7 TIA port, configurable/integrated, from version V12 / V12
● STEP 7 configurable/integrated, from version V5.5 SP2/-
● GSD version PROFIBUS or later V1.0 / V5.1
● GSD version PROFINET or later v2.3 / -
operation mode
● oversampling no
● MSI yes
CiR configuration in operation
you can change parameter assignment in RUN mode. Yes
can be calibrated in RUN mode yes
power supply voltage
voltage type of power supply DC
rating (DC)24V
allowed range, lower limit (DC)20.4v
allowed range, upper limit (DC)28.8V
reverse polarity protection yes
input current
current consumption, maximum240 mA; 24V DC power supply
sensor power supply
24V sensor power supply
● Short Circuit Protection yes
● output current, maximum20 mA; Maximum 47 mA per channel, duration <10 s
power
power output from backplane bus0.7W
power loss
power loss, typical2.7W
analog input
number of analog inputs8
● current measurement8
● voltage measurement8
● When measuring resistance/resistance thermocouple4
● When measuring thermocouple8
voltage input allowed input voltage (damage limit), maximum28.8V
current input allowable input current (damage limit), maximum40 mA
constant measured current of resistance sensor, typical value150 Ohm,300 Ohm,600 Ohm,Pt100,Pt200,Ni100:1.25 mA,6000 Ohm,Pt500,Pt1000,Ni1000,LG-Ni1000:0.625 mA,PTC:0.472 mA
technical unit of temperature measurement, adjustable yes; °C/°C/K
input range (rated value), voltage
● 0 to +5V no
● 0 to +10V no
● 1V to 5V yes
● input resistance (1V to 5V)100 k? 6? 8
● -1v to +1v yes
● input resistance (-1V to +1V)10 M? 6? 8
● -10V to +10V yes
● input resistance (-10V to +10V)100 k? 6? 8
● -2.5V to +2.5V yes
● input resistance (-2.5V to +2.5V)10 M? 6? 8
● -25 mV to +25 mV no
● -250 mV to +250 mV yes
● input resistance (-250 mV to +250 mV)10 M? 6? 8
● -5V to +5V yes
● input resistance (-5V to +5V)100 k? 6? 8
● -50 mV to +50 mV yes
● input resistance (-50 mV to +50 mV)10 M? 6? 8
● -500 mV to +500 mV yes
● input resistance (-500 mV to +500 mV)10 M? 6? 8
● -80 mV to +80 mV yes
● input resistance (-80 mV to +80 mV)10 M? 6? 8
input range (rated value), current
● 0 to 20 mA yes
● input resistance (0 to 20 mA)25? 6? 8; Plus about 42Ohm for over-voltage protection through PTC
● -20 mA to +20 mA yes
● input resistance (-20 mA to +20 mA)25? 6? 8; Plus about 42Ohm for over-voltage protection through PTC
● 4 mA to 20 mA yes
● input resistance (4 mA to 20 mA)25? 6? 8; Plus about 42Ohm for over-voltage protection through PTC
input range (rating), thermocouple
● Type B yes
● input resistance (type B)10 M? 6? 8
● Type C no
● Type E yes
● input resistance (Type E)10 M? 6? 8
● Type J yes
● input resistance (Type J)10 M? 6? 8
● Type K yes
● input resistance (Type K)10 M? 6? 8
● Type L no
● Type N yes
● input resistance (Type N)10 M? 6? 8
● Type R yes
● input resistance (Type R)10 M? 6? 8
● Type S yes
● input resistance (Type S)10 M? 6? 8
● Type T yes
● input resistance (Type T)10 M? 6? 8
● type TXK/TXK(L) conforms to GOST no
input range (rated value), resistance thermometer
● Cu 10 no
● Cu 10 conforming to GOST no
● Cu 50 no
● Cu 50 conforming to GOST no
● Cu 100 no
● Cu 100 conforming to GOST no
● Ni 10 no
● Ni 10 conforming to GOST no
● Ni 100 yes; Standard/climate
● input resistance (Ni 100)10 M? 6? 8
● Ni 100 conforming to GOST no
● Ni 1000 yes; Standard/climate
● input resistance (Ni 1000)10 M? 6? 8
● Ni 1000 conforming to GOST no
● LG-Ni 1000 yes; Standard/climate
● input resistance (LG-Ni 1000)10 M? 6? 8
● Ni 120 no
● Ni 120 conforming to GOST no
● Ni 200 conforming to GOST no
● Ni 500 no
● Ni 500 conforming to GOST no
● Pt 10 no
● Pt 10 conforming to GOST no
● Pt 50 no
● Pt 50 conforming to GOST no
● Pt 100 yes; Standard/climate
● input resistance (Pt 100)10 M? 6? 8
● Pt 100 conforming to GOST no
● Pt 1000 yes; Standard/climate
● input resistance (Pt 1000)10 M? 6? 8
● Pt 1000 conforming to GOST no
● Pt 200 yes; Standard/climate
● input resistance (Pt 200)10 M? 6? 8
● Pt 200 conforming to GOST no
● Pt 500 yes; Standard/climate
● input resistance (Pt 500)10 M? 6? 8
● Pt 500 conforming to GOST no
input range (rated value), resistance
● 0 to 150 Ohm yes
● input resistance (0 to 150 ohm)10 M? 6? 8
● 0 to 300 ohm yes
● input resistance (0 to 300 ohm)10 M? 6? 8
● 0 to 600 ohm yes
● input resistance (0 to 600 ohm)10 M? 6? 8
● 0 to 3000 Ohm no
● 0 to 6000 Ohm yes
● input resistance (0 to 6000 Ohm)10 M? 6? 8
● PTC yes
● input resistance (PTC)10 M? 6? 8
thermocouple (TC)
temperature compensation
-Parameterizable yes
-Internal temperature compensation yes
-External temperature compensation using RTDs yes
-0°C comparison point temperature compensation yes; You can set a fixed value.
-Module reference channel yes
wire Length
● shielding, maximum800 m; In U/I, 200 m at R/RTD and 50 m at TC
analog value composition at input
integration and conversion time/resolution per channel
● resolution with overmodulation (digits including symbols), maximum16 bit
● parameterized integration time yes
● integral time (ms)2,5 / 16,67 / 20 / 100 ms
● Basic conversion time, including integration time (ms)9 / 23 / 27 / 107 ms
-Additional switching time for disconnection monitoring9ms (for R/RTD/TC measurement)
-Additional Conversion time for resistance measurement150 Ohm, 300 Ohm, 600 Ohm, Pt100, Pt200, Ni100: 2 ms, 6000 Ohm, Pt500, Pt1000, Ni1000, LG-Ni1000, PTC: 4 ms
● suppression of interference voltage at interference frequency f1 (unit Hz)400 / 60 / 50 / 10Hz
● offset calibration time (each module) basic conversion time of the slowest Channel
measured value filtering
● parameterizable yes
● level: None yes
● level: weak yes
● grade: Medium yes
● level: Strong yes
sensor
signal sensor connection
● used for voltage measurement yes
● current measurement as a two-wire measuring transmitter yes
-Double-line measurement of the load of the frequency converter, maximum value820? 6? 8
● current measurement as a four-wire measuring transmitter yes
● For resistance measurement using two-wire interface yes; Only for PTC
● Resistance measurement using three-wire interface yes; All measurement ranges outside PTC; Internal compensation of cable resistance
● Resistance measurement using four-wire interface yes; All measurement ranges outside PTC
error/precision
linear Error (related to input range),(+/-)0.02%
temperature error (related to input range),(+/-)0.005 %/K; 0.02 ± % /K for TC type T
crosstalk between input terminals, maximum-80 dB
repetition accuracy in the starting state at 25°C (related to the input range),(+/-)0.02%
internal compensated temperature failure± 6°C
operating error limits over the entire temperature range
● voltage, related to the input range,(+/-)0.3%
● Current, related to the input range,(+/-)0.3%
● Resistance, related to the input range,(+/-)0.3%
● Resistance Temperature, related to the input range,(+/-) Ptxxx standard: ± 1.5 K,Ptxxx climate: ± 0.5 K,Nixxx standard: ± 0.5 K,Nixxx climate: ± 0.3 K
● thermocouple, related to the input range,(+/-) type B: > 600°C ± 4.6 K, Type E: > -200°C ± 1.5 K, Type J: > -210°C ± 1.9 K, Type K: > -200°C ± 2.4 K, type N: > -200°C ± 2.9 K, Type R: > 0°C ± 4.7 K, Type S: > 0°C ± 4.6 K, type T: > -200°C ± 2.4 K
basic error limit (Operation error limit at 25°C)
● voltage, related to the input range,(+/-)0.1%
● Current, related to the input range,(+/-)0.1%
● Resistance, related to the input range,(+/-)0.1%
● Resistance Temperature, related to the input range,(+/-) Ptxxx standard: ± 0.7 K,Ptxxx climate: ± 0.2 K,Nixxx standard: ± 0.3 K,Nixxx climate: ± 0.15 K
● thermocouple, related to the input range,(+/-) type B: > 600°C ± 1.7 K, Type E: > -200°C ± 0.7 K, Type J: > -210°C ± 0.8 K, Type K: > -200°C ± 1.2 K, type N: > -200°C ± 1.2 K, Type R: > 0°C ± 1.9 K, Type S: > 0°C ± 1.9 K, type T: > -200°C ± 0.8 K
fault voltage suppression f = n x (f1 +/- 1 %),f1 = interference frequency
● series interference (interference peak <Input range rating), minimum40 dB
● parallel voltage, maximum10V
● Common Code interference, minimum60 dB
isochronous mode
Beat synchronization (Application to Port synchronization) no
alarm/diagnosis/status information
diagnostic function yes
alarm
● diagnostic alarm yes
● limit value alarm yes; Two upper limits and two lower limits respectively
diagnostic Information
● power supply voltage monitoring yes
● disconnection yes; Only 1 ... 5V,4 ... 20 mA,TC, R, and RTD
● overflow/underflow yes
diagnostic display LED
● RUN LED yes; Green LED
● ERROR LED yes; Red LED
● power supply voltage monitoring (PWR-LED) yes; Green LED
● Channel Status Display yes; Green LED
● For Channel diagnosis yes; Red LED
● used for module diagnosis yes; Red LED
potential isolation
potential separation of channels
● between channels no
● group points between channels8
● between the Channel and the backplane bus yes
● between the Channel and the power supply voltage of electronic components yes
allowable potential difference
between input terminals (UCM) DC 20V
between the input and MANA (UCM)10V DC
insulation
insulation Test, use707V DC (test type)
standards, licenses, certificates
applicable to AMS2750-compliant applications yes; For more information about compliance statements, see online support documentation 109757262.
Applicable to CQI-9-compliant applications yes; Based on AMS 2750 E
environmental requirements
operating ambient temperature
● horizontal installation, minimum0°C
● horizontal installation, maximum60°C
● vertical installation, minimum0°C
● vertical installation, maximum40°C
distributed operation
start by priority no
size
width35 mm
height147 mm
depth129 mm
weight
weight, about310g
other
tips: additional basic faults and noise during integration time = 2.5ms: Voltage: ± 250mV (± 0.02%), ± 80mV (± 0.05%), ± 50mV (± 0.05%), resistance: 150Ohm ± 0.02%, resistance thermometer: Pt100 climate: ± 0.08K, Ni100 climate: ± 0.08K, thermocouple: type B, R, S: ± 3K, Type E, J, K, N, T:± 1K
last modification:2019/4/12
Click To Contact Yiwugo's Partner To Get Trade Service
©2024 Yiwugo.com All rights reserved.
Finding high quality products in Yiwu China, Yiwu China Commodity Market (Yiwu wholesale market), the World's Largest Commodities Trading Center Online.
TEL: +86-579-81530000 FAX: 86-579-85188202 网站备案号:浙ICP备15028362号-7

TOP

Items have been added to the Inquiry Basket

There are items in the inquiry basket

Continue shopping Send Inquiry