Product Name: Siemens S7-300...
CPU312C, 10DI/6DO, 64 KB
Product Information:
SIMATIC S7-300,CPU 312C compact CPU mit MPI, 10 DE/6 DA, 2 schnelle counter(10 kHz) integr. Power supply DC 24V working memory64 KByte front connector(1x 40 pole) and miniature memory cards
Technical data:
General information
Hardware function status 1
Firmware version V3.3
With package
● engineering System STEP 7 V5.5 + SP1 above or STEP 7 V5.3 + SP2 above, attached HSP 203
Power supply voltage
Rating(DC)
● DC 24V yes
Allowed range, lower limit(DC) 19.2V
Allowed range, upper limit(DC) 28.8V
External safety device for power conductor (recommended) LS switch, type C, minimum value2 A; LS switch, type B, minimum value4 A
Power supply and voltage open circuit jumper
● power failure/ power off crossover time5 ms
● repetition rate, minimum 1 S
Load voltage L+
Digital Output
- rating(DC) 24V
- reverse polarity protection no
Input current
Current consumption (rated value) 570 mA
Consumption current (no-load), typical value 90 mA
On current, typical value 5 A
I2t 0.7 A2·s
Digital Output
● from load voltage L+, maximum value 25 mA
Power loss
Power loss, typical 8W
Memory
Working memory
● integration 64 kbyte
● scalable no
● the size of the residual magnetic memory used for the remaining data module. 64 kbyte
Loading memory
● plug-in type(MMC) yes
● plug-in type(MMC), maximum value8 Mbyte
● MMC data management on (after the last programming), minimum 10 y
Buffer
● existence yes; pass MMC guarantee (maintenance free)
● without battery yes; programs and data
CPU- processing time
For bit operations, typical values 0.1 μs
Typical values for word operations 0.24 μs
For fixed-point operations, typical values 0.32 μs
For floating-point operations, typical values 1.1 μs
CPU- component
Number of components (total) 1 024;( DB, FC, FB); You can use MMC reduce the maximum number of loadable blocks.
DB
● quantity, maximum 1 024; digital bar:1 to16000
● capacity, maximum 64 kbyte
FB
● quantity, maximum 1 024; digital bar:0 to7999
● capacity, maximum 64 kbyte
FC
● quantity, maximum 1 024; digital bar:0 to7999
● capacity, maximum 64 kbyte
OB
● description see actions list
● capacity, maximum 64 kbyte
● available cycle OB quantity1; OB 1
● time alarm OB quantity1; OB 10
● delay alarm OB quantity2; OB 20, 21
● wake-up warning OB quantity4; OB 32,33,34,35
● process alarm OB quantity1; OB 40
● start OB quantity1; OB 100
● asynchronous error OB quantity4; OB 80,82,85,87
● synchronization error OB quantity2; OB 121,122
Nesting Depth
● each priority level 16
● error OB additional levels in4
Counter, timer and its remanence
S7 counter
● quantity 256
Remanence
-Adjustable yes
- lower limit 0
- upper limit 255
- preset Z 0 to Z 7
Counter range
- lower limit 0
- upper limit 999
IEC counter
● quantity unlimited (only through RAM limit)
S7 time
● quantity 256
Remanence
- adjustable yes
- lower limit 0
- upper limit 255
- preset no surplus
Time range
- lower limit 10 ms
- upper limit 9 990 s
IEC timer
● existence yes
● type SFB
● quantity unlimited (only through RAM limit)
Data range and its remanence
Data range can be retained, all all, maximum64 kb
Mark
● quantity, maximum 256 byte
● presence of remanence yes; MB 0 to MB 255
● preset remanence MB 0 to MB 15
● number of timing marks 8; 1 marked bytes
Data Components
● quantity, maximum 1 024; digital bar:1 to16000
● capacity, maximum 64 kbyte
● adjustable remanence yes; in DB does not retain features in
● preset remanence yes
Local data
● each priority level, maximum 32 kbyte; maximum Value per block2048 bytes
Address range
Peripheral address range
● input 1 024 byte
● output 1 024 byte
Distributed
- input none
- output none
Process Image
● input 1 024 byte
● output 1 024 byte
● input, adjustable 1 024 byte
● output terminal, adjustable 1 024 byte
● input, preset 128 byte
● output, preset 128 byte
The default address of the integration channel.
- digital input 124.0 to125.1
- digital Output 124.0 to124.5
Digital channel
● input 266
- centralized 266
● output 262
- centralized 262
Analog Channel
● input 64
- centralized 64
● output 64
- centralized 64
Hardware extension
Number of extended supports, maximum 0
DP number of master stations
● integration none
● about CP 4
Runnable FM and CP quantity (recommended)
● FM 8
● CP, PtP 8
● CP, LAN 4
● quantity 1
● number/ digital bar 0
● value range 0 to2 the31 power Hour (in use SFC 101 time)
● interval size 1 hours
● remaining yes; you must restart each time you restart
Number of digital inputs 10
● inputs that can be used to implement technical functions 8
Integrated Channel(DI) 10
Input characteristics conform IEC 61131, type1 yes
Number of input terminals that can be controlled at the same time
Horizontal installation position
- up40℃, maximum 10
- up60℃, maximum 5
Vertical Installation position
- up40℃, maximum 5
Input voltage
● rating(DC) 24V
● for signal0" -3 to+5V
● for signal1" +15 to+30V
Input current
● for signal1", typical value 8 mA
Input delay (when the input voltage is rated)
For standard input
- parameterizable yes; 0.1 / 0.3 / 3 / 15ms(During the program running time, you can configure the input delay of the standard input again. Note that the reset filtering time may not take effect until the previous filtering time completes a cycle.)
- rating 3 ms
For counters/ technical functions
- from0"To"1 maximum value 48 μs; minimum pulse width at maximum count frequency/ minimum pulse interval
Wire Length
● mask, maximum 1 000 m; 100 m for technical functions
● unshielded, maximum 600 m; for technical functions: no
For technical functions
- mask, maximum 100 m; at the maximum count frequency
- unshielded, maximum not allowed
Digital Output
Number of digital outputs 6
● the fast output 2; note: Do not connect in parallel CPU fast output
Integrated Channel(DO) 6
Short circuit protection yes; electron pulse
● response threshold, typical value 1 A
Limit of inductive shutdown voltage L+ (-48 V)
Control digital input yes
On-off capability of output terminal
●Maximum lighting load 5W
Load resistance range
● lower limit 48
● upper limit 4 K
Output voltage
● for signals"1", minimum value L+ (-0.8 V)
Output Current
● for signal1"Rating 500 mA
● for signal1 allowed range, minimum value 5 mA
● for signal1 allowed range, maximum 0.6 A
● for signal1 minimum load current 5 mA
● for signal0"Residual current, maximum value 0.5 mA
Two output terminals are connected in parallel
● used to increase power no
● used for redundant load control yes
Switching frequency
● maximum value of resistance load 100Hz
● maximum value of inductive load 0.5Hz
● maximum lighting load 100Hz
● pulse output terminal of resistance load, maximum value 2.5 kHz
Total current at the output terminal (each group)
Horizontal installation position
- up40℃, maximum 2 A
- up60℃, maximum 1.5 A
Vertical Installation position
- up40℃, maximum 1.5 A
Wire Length
● mask, maximum 1 000 m
● unshielded, maximum 600 m
Analog input
Number of analog inputs 0
Integrated Channel(AI) 0
Analog output
Number of analog outputs 0
Integrated Channel(AO) 0
Sensor
Connectable sensor
● two-wire sensor yes
- allowable closed circuit current (two-wire sensor) maximum 1.5 mA
Interface
Number of Industrial Ethernet interfaces 0
RS 485 number of interfaces 1; MPI
RS 422 number of interfaces 0
1. Interface
Interface Type integration RS 485 interface
Physical composition RS 485
Potential isolation no
Power supply at the interface (15 to30V DC), maximum value200 mA
Functionality
● MPI yes
● PROFIBUS DP main Station no
● PROFIBUS DP slave station no
● point-to-point connection no
MPI
● transmission rate, maximum 187.5 kbit/s
Service
- PG/OP communication yes
- routing no
- global Data Communication yes
- S7 basic communication yes
- S7 communication yes; server only, single-side configuration connection
- S7 communication, as a client no; but about CP and loadable FB
- S7 communication, as a server yes
Communication function
PG/OP communication yes
Dataset routing no
Global Data Communication
● support yes
● GD number of circles, maximum 8
● GD number of packages, maximum 8
● GD number of packets, Sender, maximum 8
● GD number of packets, receiver, maximum 8
● GD package size, maximum 22 byte
● GD package size (consistency), maximum 22 byte
S7 basic communication
● support yes
● valid data for each task, maximum 76 byte
● valid data for each task (consistency), maximum 76 byte; 76 bytes ( X_SEND or X_RCV);64 bytes ( X_PUT or X_GET as a server)
S7Communication
● support yes
● as a server yes
● as a client yes; pass CP and loadable FB
● valid data for each task, maximum 180 byte;( PUT/GET)
● valid data for each task (consistency), maximum 240 byte; as a server
S5 compatible communication
● support yes; pass CP and loadable FC
Number of connections
● all 6
● applicable PG communication 5
- for PG communication Reservation 1
- adjustable PG communication, minimum 1
- adjustable PG communication, maximum 5
● available OP communication 5
- for OP communication Reservation 1
- adjustable OP communication, minimum 1
- adjustable OP communication, maximum 5
● applicable S7 basic communication 2
- for S7 Basis communication Reservation 0
- adjustable S7 Basis communication, minimum 0
- adjustable S7 basic communication, maximum 2
S7 message function
The maximum number of registrable sites for the message function. 6; depends on the pair PG/OP and S7 configuration connection of basic communication
Process diagnosis message yes
Alerts for activities at the same time S component, maximum 300
Debugging function test
Component Status yes; at most at the same time2 A
Each step yes
Number of stop points 4
Status/ control
● variable Status/ control yes
● variable input, output, tag, DB, timer, counter
● number of variables, maximum 30
- the state of the variable, the maximum value 30
- variable control, maximum 14
Mandatory
● mandatory yes
● force, variable input and output
● number of variables, maximum 10
Diagnostic buffer
● existence yes
● number of Entries, maximum 500
- adjustable no
- power outage insurance 100; keep only the last100 entries
● RUN the maximum number of entries that can be read in the mode. 499
- adjustable yes; 10 to499
- preset 10
Maintenance data
● readable yes
Alarm/ diagnosis/ status Information
Diagnostic display LED
● digital input status display (green) yes
● digital Output status display (green) yes
Integration function
Number of counters 2; see technical functions in the manual"
Count frequency (counter), maximum 10 kHz
Frequency Measurement yes
Frequency meter quantity 2; maximum10 kHz(See manual "technical functions")
Control positioning no
Integrated Functional components (adjustment) no
PID regulator no
Number of pulse outputs 2; maximum pulse width modulation2.5 kHz(See manual "technical functions")
Limit frequency (Pulse) 2.5 kHz
Potential isolation
Digital input potential isolation
● digital input potential isolation yes
● between channels no
● between the channel and the backplane bus yes
Digital output potential isolation
● digital output potential isolation yes
● between channels no
● between the channel and the backplane bus yes
Insulation
Insulation Test, use DC 600V
Environmental requirements
Operating ambient temperature
● minimum value 0° C
● maximum 60° C
Configuration
Configuration software
● STEP 7 yes; STEP 7 V5.5 + SP1 above or STEP 7 V5.3 + SP2 above, attached HSP 203
● STEP 7-Lite no
Programming language
- KOP yes
- FUP yes
- AWL yes
- SCL yes
- GRAPH yes
- HiGraph® yes
Technical Protection
● user program protection/ password protection yes
● module encryption yes; equipped S7-Block Privacy
Size
Width 80 mm
Height 125 mm
Depth 130 mm
Weight
Weight, about 410g