OMS/2000/2K/HMS/BM5 Orbital Hydraulic Motor |
||||||||||
|
Displacement(ml/r) |
80 |
100 |
125 |
160 |
195 |
245 |
305 |
395 |
500 |
|
|
Flow(LPM) |
Continuous |
75 |
75 |
75 |
75 |
75 |
75 |
75 |
75 |
75 |
|
Intermittent |
85 |
95 |
95 |
115 |
115 |
115 |
115 |
130 |
130 |
|
|
Speed(RPM) |
Continuous |
850 |
675 |
552 |
430 |
345 |
287 |
231 |
178 |
142 |
|
Intermittent |
956 |
855 |
700 |
660 |
529 |
423 |
347 |
308 |
246 |
|
|
Pressure(Mps) |
Continuous |
17.5 |
17.5 |
17.5 |
17.5 |
17.5 |
17.5 |
15 |
15 |
12 |
|
Intermittent |
28 |
28 |
28 |
25 |
25 |
25 |
21 |
175 |
15 |
|
|
Torque(N*m) |
Continuous |
178 |
223 |
278 |
356 |
445 |
557 |
580 |
715 |
720 |
|
Intermittent |
285 |
356 |
445 |
509 |
636 |
755 |
763 |
840 |
860 |
|
1.Intermittent means the entrance of the maximum pressure;continuous working pressure means the differential pressure.
2.Motor should not work under the highest pressure and the maximum speed.
3.The running time should not exceed 10% under interoittent working conditions.
4.The maximum working temperature is 80°.
5.The maximum allowable back pressure is 10MPa,but the recommended back pressure should not exceed 5MPa.a leaking pipes is needed when exceeding.
6.One hour running time under 40% of maximum working pressure is recommended before full capacity working.
7.Recommending N68 anti-wear hydraulic oil,viscosity37-73cSt,cleanliness ISO18/13.