Main information
product line
Modicon M221
product category
programmable controller
Rated power supply voltage [Us]
24 V DC
Discrete input quantity
14. Discrete input 4. Fast input conforms to IEC 61131-2, type 1.
Analog input quantity
2 0...10 V on ...
Solid-state output type
transistor
Discrete output quantity
10 Transistor 2 Fast Output
Discrete output voltage
24 V DC
Discrete output current
0.5 A
additional information
Discrete I/O number
24
I/O expansion module number
7 (local I/O system)
14 (remote I/O system)
Power supply voltage range
20.4…28.8 V
Instantaneous peak current
35 A
Power consumption [W]
14 W on … 24 V (maximum number of I/O expansion modules)
4.8 W on … 24 V (without I/O expansion module)
Power supply output current
0.52 A 5 V applicable expansion bus
0.2 A 24 V applicable expansion bus
Discrete input logic
Well or source (positive/negative)
Discrete input voltage
24 V
Discrete input voltage type
direct current
Analog input resolution
10 bits
LSB value
10 mV
switching time
1 ms per channel+1 controller cycle time is used for analog input.
Allowable overload of input terminal
+/- 30 V DC for 5 minutes (maximum) for analog input.
+/- 13 V DC (constant) is suitable for analog input.
Voltage state 1 guarantee
> = 15 V applicable input
Voltage state 0 guarantee
< = 5 V applicable input
Discrete input current
7 mA suitable for discrete input
5 mA for fast input
input impedance
3.4 kOhm is suitable for discrete input
100 kOhm is suitable for analog input.
4.9 kOhm is suitable for fast input.
Response time
35 µs off, I2...I5 terminal for input.
5 µs on, terminals I0, I1, I6, I7 and I7 are suitable for fast input.
35 µs open, other terminals are suitable for input.
5 µs off, terminals I0, I1, I6, I7 and I7 are suitable for fast input.
100 µs off, other terminals are suitable for input.
5s on, off, Q0...Q1 terminals are suitable for output.
50 µs on, off, Q2...Q3 terminal suitable for output.
300 µs on and off, other terminals are suitable for output.
Configurable filtering time
0 ms applicable input
3 ms applicable input
12 ms applicable input
Discrete output logic
Positive logic (source)
Connection type-terminal connection
5 A
Output frequency (synchronous with main frequency)
100 kHz is suitable for fast output (PWM/PLS mode) at Q0...Q1 terminal on ...
5 kHz is suitable for output on Q2...Q3 terminal.
0.1 kHz is suitable for output at Q4...Q9 terminal on ...
Absolute accuracy error
+/- 1% full scale for analog input.
Maximum leakage current
0.1 mA for transistor output
Maximum voltage drop
<1 V
mechanical life
200000000 times for transistor output
Maximum tungsten load
< 12 W suitable output and fast output
Protection type
Overload and short circuit protection on ... 1 A
Reset time
1 s automatic reset
storage capacity
256 kB for user data and device RAM and 10000 instructions.
256 kB for internal variable RAM.
data backup
256 kB built-in flash card is suitable for application and data backup.
Data storage device
2 GB SD card (optional)
Battery type
BR2032 or CR2032X lithium battery is not charged.
Cumulative running time
1 year at … 25 °C (by interrupting the power supply)
Execution time of 1K instruction
0.3 ms applies to events and periodic tasks.
_
0.2 µs _
Execution time of each task
60 µs response time
Maximum target area size
255 %C counter
512 %M memory bits
8000 %MW memory words
512 %KW continuous words
255 %TM timer
real-time clock
have
Clock error
< = 30 s/ month 25 °C on ...
regulating loop
Adjustable PID regulator up to 14 synchronization cycles
Positioning function
PTO 2 Pulse/Direction Mode (100 kHz)
PTO 1 CW/CCW mode (100 kHz)
Available functions
Frequency generator
PLS
PWM
Calculate the number of inputs
4 Fast input (high count mode) 32 bits at 100 kHz on …
counter function
A/B
monophase
Pulse/direction
Integrated connection type
USB port and mini B USB 2.0 connector
Non-isolated serial link serial 1 and RJ45 connectors and RS232/RS485 interface.
Ethernet and RJ45 connectors
Power Supply
(continuous) serial link power supply: 5 V, <200 mA.
transmission rate
1.2...115.2 kbit/s (default 115.2 kbit/s) is used for bus length of ... 15m, and RS485 is applicable.
1.2...115.2 kbit/s (115.2 kbit/s by default) is used for bus length of ... 3m, and RS232 is applicable.
480 Mbit/s is suitable for USB.
protocol
USB port: USB protocol-SoMachine-Network
Non-isolated serial link: serial Modbus protocol master/slave-RTU/ASCII or SoMachine-Network.
: Ethernet protocol
Ethernet port
10BASE-T/100BASE-TX 1 port and 100 m copper cable.
Communication service
TCP slave device of network communication protocol
Modbus TCP server
Modbus TCP customers
Ehternet/IP converter
DHCP client
Local signal indication
1 LED (green) for PWR:
1 LED (green) for RUN:
1 LED (red) for module ERRor (err):
1 LED (green) for accessing SD card (SD):
1 LED (red) for BAT:
1 LED per channel (green) for I/O status:
1 LED (green) for SL:
Ethernet activity (green) for ACT:
Ethernet network connection (yellow) for link (link status):
electrical connection
The detachable spiral terminal is used for input.
The detachable spiral terminal is used for output.
Terminal, 3 terminals are used to connect 24 V DC power supply.
Connector, 4 terminals for analog input
Mini B USB 2.0 connector to a programming terminal
Maximum cable distance between devices
Shielded cable: < 10 m is suitable for fast input.
Unshielded cable: < 30 m for output.
Unshielded cable: < 30 m is suitable for digital signal input.
Unshielded cable: < 1 m for analog input.
Shielded cable: < 3 m for fast output.
isolation;quarantine
500 V AC between input and internal logic on …
Between fast input and internal logic, 500 V AC on …
There is no isolation between inputs
500 V AC between output and internal logic on …
Non-insulation between analog input and internal logic
Non-insulated between similar inputs
sign
CE
Installation mode
Top hat type TH35-15 Guide rail installation conforms to IEC 60715.
Top hat type TH35-7.5 Guide rail installation conforms to IEC 60715.
Plate or plate with fixing sleeve
height
90 mm
depth
70 mm
width
110 mm
net weight
0.395 kg
ambient temperature
-10 … 55 C (vertical installation)
-10 … 35 C (vertical installation)
Storage ambient temperature
-25…70 °C
relative humidity
10…95%, no condensation (in operation)
10…95%, no condensation (storage period)
IP protection level
IP20 protective cover in place
class of pollution
<= 2
Working altitude
0...2000 m
Storage height
0…3000 m
Vibration resistance
3.5 mm on … 5…8.4 Hz on … Uniform guide rail.
3.5 mm on … 5…8.4 Hz on … panel installation.
1 gn 8.4 8.4…150 Hz on ... Uniform guide rail on ...
1 gn 8.4 8.4…150 Hz on ... Install on the upper panel of ...
resist the impact
147 m/s for 11 ms
TOP
Items have been added to the Inquiry Basket