Search history
Clear allSearch by image
XDrag and drop an image here or upload an image
Max 5MB per image
UploadSign In | Join
X Email Mobile
1-way 5v red plate
|
CN¥ 2.33 | 87318 piece available |
|
1-way 12v red plate
|
CN¥ 2.35 | 90415 piece available |
|
1-way 24v red plate
|
CN¥ 2.45 | 43649 piece available |
|
2-way 5v red plate
|
CN¥ 4.66 | 65324 piece available |
|
2-way 12v red plate
|
CN¥ 4.71 | 70962 piece available |
|
2-way 24v red plate
|
CN¥ 4.79 | 81213 piece available |
|
4-way 5v red plate
|
CN¥ 9.16 | 75796 piece available |
|
4-way 12v red plate
|
CN¥ 9.22 | 75515 piece available |
|
4-way 24v red plate
|
CN¥ 9.46 | 79272 piece available |
|
8-way 5v red plate
|
CN¥ 18.48 | 81126 piece available |
|
8-way 12v red plate
|
CN¥ 18.48 | 78756 piece available |
|
8-way 24v red plate
|
CN¥ 18.98 | 81392 piece available |
|
A new item has been added to your Shopping Cart. You now have items in your Shopping Cart.

请提供需要翻译的中文描述,我将为您翻译成英文。
Chinese description:
Module Description:
1. The module uses relays with large open contacts for high-load AC applications.250V/10ADC30V/10A";
2. Adopts SMD photocoupler isolation, with strong driving capability and stable performance.触发电流5mA;
3. Module operating voltage5V、12V、24VAvailable for selection.
4. The module can be set to trigger with high or low logic levels using jumpers.
5. Fault-tolerant design, even if the control line is broken, the relay will not operate;
6. Power indicator (green), relay status indicator (red)
7. The interface design is humanized, and all interfaces can be directly connected through terminal strips, which is very convenient.
8. Module Size:50mm * 26mm * 18.5mmLength * Width * Height
9. There are four fixed bolt holes, with a diameter of 3.1mm, and the spacing is 44.5mm * 20.5mm.
Module Interface:
1、DC+:Connect to the positive power supplyThe voltage can be selected according to the requirements of the relay, with options of 5V, 12V, and 24V.
2、DC-:Connect to the negative power supply
3. IN: The relay can be controlled to make or break by high or low level.
Relay Output Terminal:
1. NO: Relay normally open interface, before the relay engages, it is floating, and after engagement, it is short-circuited to COM.
2、COM:Relay Common Interface
3. NC: Relay normally closed interface, short-circuited to COM before the relay engages, and floated after engagement.
High-low level trigger selection terminal:
1. When the jumper is short-circuited to LOW, it triggers at low voltage.
2. When the jumper is shorted to high, it is a high-level trigger.
III. Technical Specifications:
Relay version static current, large current trigger voltage (low), high
5V5mA 190mA 2-4mA 0-1.5V2.5-5V
12V5mA80mA 2-4mA0-4V 4.5-12V
24V5mA 50mA2-4mA 0-8V, 8.5-24V
English description:
product description:
A module description:
1, the module uses genuine high-quality relays, the maximum load of the normally open interface: AC 250V/10A, DC 30V/10A;
2, using patch optocoupler isolation, strong driving ability, stable performance; trigger current 5mA;
3, the module working voltage is available in 5V, 12V, 24V;
4. The module can be triggered by a jumper to set a high level or a low level;
5, fault-tolerant design, even if the control line is broken, the relay will not move;
6, power indicator (green), relay status indicator (red)
7, the interface design is user-friendly, all interfaces can be directly connected through the terminal block, very convenient
8, module size: 50mm * 26mm * 18.5mm (length * width * height)
9, with 4 fixing bolt holes, hole 3.1mm, spacing 44.5mm*20.5mm
Two module interface:
1. DC+: Connect the positive pole of the power supply (the voltage is selected according to the relay, and there are 5V, 12V and 24V options)
2, DC-: connected to the negative pole of the power supply
3, IN: 可以控制继电器拉高或拉低
Relay output:
1. NO: The relay normally open interface, the relay is suspended before the suction, and the short is connected with COM after the suction.
2, COM: relay common interface
3. NC: The relay normally closes the interface, and the relay is shorted to COM before the suction is closed.
High and low trigger selection:
1. 当跳线短接到LOW时,它由低电平触发;
2. When the jumper is shorted to high, it is triggered by a high level.
Third, technical parameters:
Relay version Quiescent current Maximum current Trigger current Trigger voltage (low) High
5V 5mA 190mA 2-4mA 0-1.5V 2.5-5V
12V 5mA 80mA 2-4mA 0-4V 4.5-12V
24V 5mA 50mA 2-4mA 0-8V 8.5-24V
Image display:





Update time:
TOP