Name: CPR160 Infant Resuscitation Simulator
Material: Imported thermoplastic elastomer blend adhesive
Warranty period: one year
Product Description
This product is designed based on the anatomical features and physiological characteristics of infants. Its core components include a human simulator and an electronic display screen, which allow for infant cardiopulmonary resuscitation training. It enables electronic monitoring of the volume of air blown during artificial respiration and the depth of pressure applied during chest compressions. It is an ideal product for hospitals, medical schools, health schools, and other social training institutions engaged in infant cardiopulmonary resuscitation training.
Execution standard: AHA 2015 Guidelines for International Cardiopulmonary Resuscitation (CPR) & Emergency Cardiovascular Care (ECC)
Functional features:
■ New tracheal intubation function added
■ Simulate standard airway opening.
■ Manual chest compressions display alarm:
· The pressing position is correct, but the incorrect indicator light and error alarm;
· The pressing intensity is correct (for areas greater than or equal to 2 cm), while the indicator light indicates an error (for areas less than 2 cm) and an error alert is triggered.
■ Artificial mouth-to-mouth breathing (breathing) triggers an alarm:
· The tidal volume blown in is <30ml~50ml, as indicated by the indicator light and triggered by the alarm;
· The correct indicator light display for the insufflated tidal volume is between 30ml and 50ml;
· The tidal volume blown in is too fast or excessively large, causing the gas to enter the stomach and triggering the indicator light display and alarm.
■ Press-and-breathing ratio: 3:2 for individual, or 15:2 for two people.
■ Operation cycle: Press and manual blowing at 30:2 or 15:2 for five cycles
Cycle CPR operation.
■ Operation frequency: International standard: 100 or more times per minute.
■ Operation method: Training operation.
■ Inspection of brachial artery response: Using a pressure ball, simulates the brachial artery pulse.
■ Operating status: Uses a 220V power supply. Or, a DC power from 4 AA batteries.
Operates under power supply, suitable for training in areas without power.
Standard set configuration:
One human model of a recovered infant;
One electronic display;
One portable canvas bag;
One recovery operation pad;
Barrier facial mask (50 pieces per box); 1 box;
4 sets of lung sac replacement devices;
One user manual.