X Email Mobile
EXW Price: |
|
EHAKL Electric Co.,Ltd 11yr. |
|
Main Products: |
Voltage regulator,transformer,switching power supply,circuit breaker,contactor,relay,pushbutton,switch,distribution box |
Contacts: | liuhuanChat |
Mobile: | 86-18757872323 |
WhatsApp: | 008618757872323 |
E-mail: | kevinliu@ehakl.com |
WeChat: | 690658306 |
Address: | 14015 , 12 Street, 2 F, 28 Gate, International Trade Mart (District 2). |
Address: | near National Highway 104, Liushi Town, Yueqing City, Zhejiang Province |
CD/CH Series CD701
Heating/Cooling control
Digital communication
Heating/Cooling control
Auto adjusting function
Digital communication
Big screen LED display
Industrial tandard microcomputer processor
Model Name |
1.Outline dimension
|
See the outline dimension picture | |
2.Control Mode
|
F:PID operation and auto calculating (reverse operation) | D:PID operation and auto calculating(Forward operation) |
W:eating/cooling PID operation and auto calculating(cooling water)*1 | A:heating/cooling PID operation and auto calculating(cooling water)*1 | |
3.Input mode
|
Refer to Input Range Table | |
4.Range Code
|
Refer to Input Range Table | |
5.First control
output(OUT1) (Heating side) |
M: Relay contact output V: Voltage impulse output T: Thyratron output |
8: Current output(IC4-20mA) G: Thyratron driving & triggering output |
6.Second control
output( OUT2) (Cooling side)*2 |
No mark: when the control mode is F or D M: Relay contact output V: Voltage impulse output |
T: Thyratron output 8: Current output(IC 4-20mA) |
7.First alarm(ALM1)
8.Second alarm (ALM2)*2 |
N: no alarm A: Upper-limit bias alarm B: Lower-limit bias alarm C: Upper/lower limit bias alarm D: alarm in area E: Standby upper-limit bias alarm attached F: Standby lower-limit bias alarm attached G: Standby upper/lower limit bias alarm H: Upper-limit input value alarm |
J: lower-limit input alarm K: Standby upper-limit input alarm attached L: Standby lower-limit input alarm attached P: Heater breakage alarm(CTL-6)*3 S: Heater breakage alarm(CTL-12)*3 R: Control line breakage alarm *4 V: Upper-limit set value alarm W: Lower-limit set value alarm |
9.Communication*5
|
N:No communication | 5:RS-485(two-wire system) |
10.Water-proof/dust-proof
|
N:no water-proof/dust-proof | 1:with water-proof/dust-proof |
Outline dimension
Refer to Input Range Table |
Input type
|
Set range
|
Input type
|
Set range
|
|
Thermocouple Input(TC)
|
K
|
0 to 1372°C(0 to 2502 F)
|
J
|
0 to 1200°C(0 to 2192 F)
|
R
|
0 to 1769°C(0 to 3216 F)
|
S
|
0 to 1769°C(0 to 3216 F)
|
|
B
|
0 to 1820°C(0 to 3308 F)
|
E
|
0 to 1000°C(0 to 1832 F)
|
|
N
|
0 to 1300°C(0 to 2372 F)
|
T
|
-199.9 to +400.0°C(-199.9 to +752.0 F)
|
|
W5Re/W26Re
|
0 to 2320°C(0 to 4208 F)
|
PL
|
0 to 1390°C(0 to 2534 F)
|
|
L
|
0 to 900°C(0 to 1652 F)
|
U
|
-199.9 to +600.0°C(-199.9 to +999.9 F)
|
|
RTD Input Pt
|
100Ω(JIS/IEC)
|
-199.9 to +649.0°C
(-199.9 to +999.9 F) |
JPt100Ω(JIS)
|
-199.9 to +649.0°C
(-199.9 to +999.9 F) |
Voltage input
|
0 to 5V DC
|
1 to 5V DC
|
-1999 to +9999(programmable range)
|
|
Current input
|
0 to 20mADC
|
4 to 20mADC
|
-1999 to +9999(program
|
TOP
Items have been added to the Inquiry Basket
There are items in the inquiry basket