changshu switch cm1-63l100a molded case circuit breaker contactor circuit breaker various models 中文版
  • EXW Price: Min. order:
    ¥299.0
    ≥1/piece
  • 1 piece
  • Weight 1.0 kg/piece
  • Item No. CM1-63L100A160M225H250A400A630A800H1250
  • Stock num 1000 piece
Please select a product
  Number   Unit-price   Total
I want to buy: × 299.0 = 0
The purchase quantity of each ID cannot exceed()piece
Insufficient inventory, please contact the seller
The total number of orders is less than the minimum purchase quantity(1)

A new item has been added to your Shopping Cart. You now have items in your Shopping Cart.

Continue Shopping View Shopping Cart

Yueqing Shiyu Electric Gas Co., Ltd 1yr.

Main Products:

switch,relay,Molded case circuit breaker,encoder,thermostat,Button switch,Contactor

Contacts:

wuyuChat

Mobile:

86-18248532823

WeChat:

wu5201314xion

Address:

Leqing City,Wenzhou City City,Zhejiang Province

  • Description

Packaging information

CTN Size: 90 × 40 × 40 cm

G.W./CTN:15 kg

QTY/CTN:10 piece/carton

常熟开关厂目前CM1系列产品有:CM1-63三极、四极;CM1-100三极、四极;CM1-160三极、四极 ;CM1-225三极、四极;CM1-400三极、四极;CM1-630三极、四极;CM1-800三极

 本条信息由乐清市迈创电气有限公司发布   常熟开关CM1-800H/3300塑料外壳式断路器630A700A800A/3P 常熟开关CM1-800H/3300塑料外壳式断路器空气开关800A700A630A500A CM1-800L/3300断路器尺寸 CM1-800L断路器电流CM1-800M断路器电压 CM1-800L高清图片

常熟开关CM1塑壳断路器适用范围

CM1系列塑料外壳式断路器,是采用国际 设计、制造技术研制、开发的 断路器之一。其额定绝缘电压为800V适用于交流50Hz额定工作电压690V及以下(CM1-63为400V)额定电流至800A的电路中作不频繁转换及电动机保护(CM1-800无电动机保护型)之用。断路器具有过载、短路和欠电压保护功能,能保护线路和电源设备不受损坏。 断路器按照其额定极限短路分断能力(Icu)的高低、分为C型(基本型)、L型(标准型)、M型(较高分断型)、H型(高分断型)四类。该断路器具有体积小、分断高、飞弧短(部分规格零飞弧)、抗振动等特点,并通过了核工业条件(1E级)试验和船舶条件的试验,成为国产产品中能用于核工业基地的产品,更是陆地及船舶使用的理想产品。

品牌:常熟开关 极数:3P/4P 额定频率:50(Hz) 额定绝缘电压:690(V)脱扣器电流:63-800(A) 产品认证:CCC 安装方式:插入式 速度:普通型 灭弧介质:空气式 结构:塑壳式 操作方式:手动操作

常熟开关断路器功能说明,常熟塑壳断路器CM1选型手册 常熟塑壳断路器CM1说明

常熟开关CM1系列塑壳式断路器部分型号机电流选型:

CM1-63L/3300塑壳断路器额定电流:10A,16A,20A,25A,32A,40A,50A,63A

CM1-63M/3300塑壳断路器额定电流:10A,16A,20A,25A,32A,40A,50A,63A

CM1-63M/4300塑壳断路器额定电流:10A,16A,20A,25A,32A,40A,50A,63A

CM1-100L/3300塑壳断路器额定电流:16A,20A,25A,32A,40A,50A,63A,80A,100A

CM1-100M/3300塑壳断路器额定电流:16A,20A,25A,32A,40A,50A,63A,80A,100A

CM1-100L/4300塑壳断路器额定电流:16A,20A,25A,32A,40A,50A,63A,80A,100A

CM1-160L/3300塑壳断路器额定电流:100A.125A.140A.160A

CM1-160M/3300塑壳断路器额定电流:100A.125A.140A.160A

CM1-160/4300塑壳断路器额定电流:100A.125A.140A.160A

CM1-160H/3300塑壳断路器额定电流:100A.125A.140A.160A

CM1-225L/3300塑壳断路器额定电流:100A,125A,140A,160A,180A,200A,225A

CM1-225M/3300塑壳断路器额定电流:100A,125A,140A,160A,180A,200A,225A

CM1-225M/4300塑壳断路器额定电流:100A,125A,140A,160A,180A,200A,225A

CM1-400L/3300塑壳断路器额定电流:250A,315A,350A

CM1-400M/3300塑壳断路器额定电流:250A,315A,350A

CM1-400M/4300塑壳断路器额定电流:250A,315A,350A

CM1-630L/3300塑壳式断路器额定电流:400A,500A,630A

CM1-630M/3300塑壳式断路器额定电流:400A,500A,630A

CM1-630H/3300塑壳式断路器额定电流:400A,500A,630A

CM1-630/4300塑壳式断路器额定电流:400A,500A,630A

CM1-800M/3300塑壳式断路器额定电流:630A.700A.800A

CM1-800H/3300塑壳式断路器额定电流:630A.700A.800A

以上是我们供应常熟CM1系列塑壳断路器的详细信息,如果您对我们常熟CM1系列塑壳断路器的、厂家、型号、图片有什么疑问,请联系我们获取CM1系列塑壳断路器的信息。

断路器 应用于低压配电系统中,是一种保护电器元件。在设计低压配电系统时,应注意断路器的选择性,对断路器过流脱扣器额定电流进行选择和整定,确保充分发挥过电流脱扣器的作用;当环境温度大于或小于校准温度值时,应根据制造商提供的温度与载流能力修正系数来调整低压断路器的额定电流值。

1、断路器的几种电流参数

断路器的额定电流In,是指脱扣器能长期通过的电流,也就是脱扣器额定电流。

断路器壳架等级额定电流Inm,用基本几何尺寸相同和结构相似的框架或塑料外壳中所装的脱扣器额定电流表示。它决定了所能安装的脱扣器的额定电流值。例如,DW15—1600额定电流800A的断路器,1600A是断路器的壳架等级额定电流Inm,断路器的额定电流In为800A。

过电流脱扣器可分为过载脱扣器和短路(电磁)脱扣器,有长延时动作电流(Ir1)、短延时动作电流(Ir2)和瞬时动作电流(Ir3)之分。如正泰产DW15—1600的Ir1为(0.7~1)In,Ir3为(1~3)In,没有短延时脱扣器;常熟产CW2—1600A 

的Ir1为(0.4~1)In,Ir2为(0.4~15)In+OFF,短延时时间0.1s—0.4s,共4级,Ir3为1.6KA~35 kA+OFF。 

断路器的额定极限短路分断能力(Icu):按规定的试验程序所规定的条件,不包括断路器继续承载其额定电流能力的分断能力;也就是断路器规定的试验电压及其它规定条件下的极限短路分断电流值,不考虑断路器继续承载它的额定电流。

极限短路分断能力Icu的试验程序为O—t—CO。 

其具体试验是:把线路的电流调整到预期的短路电流值(例如380V,50kA),而试验按钮未合,被试断路器处于合闸位置,按下试验按钮,断路器通过50kA的短路电流,断路器立即开断(OPEN简称O)并熄灭电弧,断路器应完好,且能再合闸。t为间歇时间,一般为3min,此时线路处于热备状态(试验按钮仍在按下状态),断路器再进行一次接通(CLOSE简称C)和紧接着的开断(O)(接通试验是考核断路器在峰值电流下的电动和热稳定性和动、静触头因弹跳的磨损)。此程序即为CO。断路器能完全分断,熄灭电弧,并无超出规定的损伤,就认定它的极限分断能力试验成功。

额定运行短路分断能力Ics,是指断路器在规定的试验电压及其它规定条件下的一种比额定极限短路分断电流小的分断电流值,在按规定的试验程序O—t—CO—t—CO动作之后,断路器应有继续承载它的额定电流的能力。它比Icu的试验程序多了一次CO。Ics是Icu的一个 数。对于 式和塑壳式断路器, 

Ics值略有不同,塑壳式允许Ics 小可以是25%Icu, 式允许Ics 小是50%的Icu,Ics=Icu的断路器是很少的。我国的DW45智能型 式断路器的Ics为62.5%~65%Icu。

2、断路器的电流整定

低压断路器过流脱扣器的额定电流应不小于线路的计算电流,即In≥Ijs (Ijs为所保护配电线路的计算电流)。

断路器的长延时动作电流(Ir1)主要是用来保护过负荷,一般情况,Ir1取线路计算电流的1.1倍,即

(Ijs为所保护的配电线路的计算电流)

短延时过流脱扣器动作电流(Ir2)应躲过线路的尖峰电流Ipk,通常按下式确定:

其中:Ipk为保护线路中1台电机的起动电流Ijs’为除起动电流的1台电机以外的线路计算电流

断路器短延时动作的整定时间通常分:0.1s、0.2s、0.3s、0.4s。为 保护装置动作的选择性,上下2级断路器的级差通常取0.1~0.2 

s,动作时间还应满足被保护线路的热效应要求。

断路器瞬时动作电流Ir3应满足Ir3≥1.3×(Ipk+ Ijs’),为满足被保护线路的断路器之间的选择性,还要求Ir3大于下一级断路器所保护的线路发生故障时的短路电流的1.1倍。

3、断路器过电流保护动作的选择性

在断路器所保护的配电系统中,当发生电气故障时,距故障点 近的断路器动作将故障切除,而其他各级断路器不动作,从而将故障所造成断电限制在 小范围内,使其它无故障供电回路仍能保持正常供电,这就是对断路器所要求的选择性。断路器的选择性在低压配电系统的设计中占有十分重要的位置,它可以给用户带来便利,并能 供电回路工作的连续性。

在低压配电系统中使用的断路器按其保护性能可分为选择性和非选择性两类。选择性低压断路器,其瞬时特性和短延时特性适用于短路动作,而长延时特性适用于过载保护。